node-red-contrib-vib-smart-valve

0.1.55 • Public • Published

Smart-valve

The purpose of this project was to replace at my house the existing NETATMO system (very good but not integrated in Home assistant and with no repeater).

I have a boiler with Opentherm Card and a dedicated dev with ESP32 https://github.com/vibr77/Opentherm_HA_MQTT

Changelog 20240102:

  • Add a mecanism for manual update on the TRV (wip)

Changelog 20231031:

  • Fixe BRT-100-TRV firmware issue (TRV wrong position stay at 25% open position) with a work around on current temperature

Smart-Valce is part of a suite of nodes to manage multi room heating system based on TRV and boiler

  • Smart-Scheduler: multi-zonning SmartScheduler,
  • Smart-Valve: Valve grouping, auto-calibration, manual override,
  • Smart-Boiler: Boiler OpenTherm, multi valve management.

Smart-valve

This node enables to manage multiple valve (climate) in a same room like one. It support the following features :

  • External temperature sensor,
  • Multiple valves updates,
  • TRV temperture Recalibration based on the external temperature sensor,
  • Manual update directly on the valve to trigger override message to the scheduler and update the other valve

Key Features:

  • TRV auto calibration with an external source
  • Detection of manual update direcly on TRV
  • Fixe BRT-100-TRV issue on valve postion that stay open
  • Multi valves in the same room management
  • Multi mode execution Off / auto / Manual
  • Multi trigger execution: every cycle, at startup, on change.

Inputs

  • payload (string):[1|on|trigger]
  • sp (integer): [0-35]

Outputs

  1. Update home assistant via call service

  2. Update of SP to the boiler (smart-Boiler) or override message to the smart-scheduler

Settings

  • Name: [string], name of the node and also the name of the group sent to the smart-boiler node

  • Topic: [string], not used,

  • Group Id: [integer], used by the smart-boiler node to identify this group of valves, need to be unique

  • Temperature: [string], is the name of the external temperature sensor entity in home assistant ex: sensor.temp9

  • Update mode: [state changed|state changed+startup|every cycle], define how frequently updates are sent to the smart-boiler node

  • Update cycle: [integer], duration in minute between two cycle. default is 5

  • Allow manual updates: [true|false], enable direct set point (target temperature) change on the valve or home assistant. If true when a valve set point ischanged all the other valves are updated and a override message is sent to the smart-scheduler node.

  • Recalibration: [No|Yes|Yes+threshold], enable to adjust the valve (TRV) current temperature based on the external temperature sensor,

  • Delta threshold: [integer] [0-9], threshold delta between external temperature sensor and the TRV current temperature to trigger recalibration,

  • Debug: [true|false], send debug info to the node-red console

  • Climate: each valve entry has 2 field:

    • climate: [string], home assitant climate entity of the valve ex: climate.kitchen
    • calibration: [string], home assistant calibration entity of the valve ex: number.kitchen_calibration

Execution rules

  • Step 0: update current group setpoint with the sp of the valve,
  • Cycle : Step 1: identify if manual updates on valve, then update all valves, Step 2: check and execute recalibration Step 3: based on the execution mode, output to the smart-boiler node
  • On input: Update the requested set-point on each valves